Setting new standards in Quality

                          Technical Specifications

Indoor Unit "Cooling only"
    G+ ITWG 007U G+ ITWG 010U G+ ITWG 012 U G+ ITWG 015 U
Indoor Unit "Heat Pump"
G+ IHWG 007U G+ IHWG 010U G+ IHWG 012 U G+ IHWG 015 U
Outdoor Unit "Cooling only" ORTC 007 G+OTS 010 G+OTS 012 G+OTS 015
Outdoor Unit "Heat Pump"   ORHC 007 G+OHS 010 G+OHS 012 G+OHS 015
Nominal Cooling Capacity kW-Btu/hr 2.20-7500 2.64-9000 3.52-12000 4.40-15000
Nominal Heating Capacity kW-Btu/hr 2.20-7500  2.52 -8600 3.52-12000 4.40-15000
Cooling Power Consumption W 990 898 1270 1750
Heating Power Consumption W 850 817 1160 1550
EER:    
Cooling* Btu/hr.w 7.58 10.02 9.45 8.57
Heating * Btu/hr.w 8.82 10.53 10.34 9.68
Power Supply V/Ph/Hz 220-240/1/50
Air Flow Rate (at high speed ) Dry coil
M3/hr
440 510 696
CFM
260 300 410
Dimensions-Indoor (WXHXD)
mm
824 x 292x 180
Dimensions-outdoor (WXHXD)
Metal (mm)
595 X 495 X 282 677 X 540 X 282 722 X 586 X 302
Plastic (mm) 605 X 485 X 290 - -
Net Weight Indoor Unit Kg 8.9
Net Weight outdoor Unit Metal (kg) 32 31 32 43
Plastic (kg) 28.5 -
Refrigerant Type   R22

 

Indoor Unit "Cooling only"
    G+ ITWG 018U G+ ITWG 020U G+ ITWG 022 U G+ ITWG 024 U
Indoor Unit "Heat Pump"
G+ IHWG 018U G+ IHWG 020U G+ IHWG 022 U G+ IHWG 024 U
Outdoor Unit "Cooling only" ORTC 018 G+OTS 020 G+OTS 022 G+OTS 025
Outdoor Unit "Heat Pump"   G+OHS 018 G+OHS 020 G+OHS 022 G+OHS 025
Nominal Cooling Capacity kW-Btu/hr 5.28 - 18000 5.72 - 19500 6.30 - 21500 7.03 -24000
Nominal Heating Capacity kW-Btu/hr 5.28 - 18000 5.72 - 19500 6.30 - 21500 7.03 -24000
Cooling Power Consumption W 2000 2000 2000 2700
Heating Power Consumption W 1730 1700 1780 2500
EER:    
Cooling* Btu/hr.w 9.00 9.75 10.75 8.89
Heating * Btu/hr.w 10.40 11.47 12.08 9.60
Power Supply V/Ph/Hz 220-240/1/50
Air Flow Rate (at high speed ) Dry coil
M3/hr
968
CFM
570
Dimensions-Indoor (WXHXD)
mm
1090 x 314 x 180
Dimensions-outdoor (WXHXD)
Metal (mm)
722 x 586 x 302 945 x 649 x 356
Plastic (mm) -
Net Weight Indoor Unit Kg 12.5
Net Weight outdoor Unit Metal (kg) 44 57.5 59 64.5
Plastic (kg) 28.5 -
Refrigerant Type   R22

 

At Nominal ASHRAE rating conditions .
Cooling : 35c outdoor  DBT / 27c indoor DBT & 19.5 c indoor WBT.
Heating::7c outdoor DBT & 80% relative humidity /20 c indoor DBT.
* Test volt: 220 for single phase at 50 Hz.
Specifications are subject to change without prior notice.

 

Indoor Unit Features
Outdoor Unit Feature
Very elegant design to suit any decoration.
 Fast installation and easy maintenance .
Energy saving with low power consumption.
Modern Cabinet design to suit the building decorations.
Ultra quiet operation.
Low noise,high efficiency compressor
Attractive LCD wireless remote controller with high transmission ability .
Advanced design allows the Ue of either " Quick Coupling" or " Flare "connection systems,for more flexibility in installation.
Advanced-technology PC-board for full control.
Heavy gauge galvanized steel with weather resistance electrostatic powder paint.
"DRY" mode reduce water vapor by computerized dehumidification.
"inner grooved" pipes and "Slit" fins increase the heat exchange rate and decrease power consumption.
"SLEEP" mode provides suitable sleeping environment with energy saving .
Available as "Cooling Only" & "Heat Pump " systems.
24 hours programmable timer controls the unit operation.
Operates in high outdoor temperatures.
Automatic & manual selection of outlet air direction.
Operates in high outdoor temperatures.
Auto selection of 3-stage indoor fan speed
Operates in low outdoor temperatures (heat pump only)
Electronic system provides 3 minutes anti short cycle protection for compressor, which guaranties total system integrity .
Optional accessories available upon request.
Hydrophilic blue coated fins in the evaporator.
- low -ambient control kit.
Self-diagnosis function.
- low - pressure protection switch.
Efficient , easy removable and cleanable air filters.

- high-pressure protection switch. 

-crankcase heater.

Options: Golden Plasma Filter :
- Carbon filters. 3 steps purifying system with pre-filter and carbon filter as follow:
- Plasma air purifying system "   Ionized Filter ". 1 -Washable pre-filter ,removing particles and dUt.
  2-Carbon Filter for odor and smoke control.
  3- Final Golden Plasma filter for :
 
Removing small particles of impurities even bacteria down to 0.01 micron releasing ions give the feeling of sea shore.

Available With Plasma Filters.

 

Copyright (c) 2007 “ Information Technology Department At Unionaire ” All rights reserved